QuelCoil Continuous Intumescent Pipe Wrap - 25m roll - outstanding value!

Quick Overview

QuelCoil Continuous Intuwrap is a universal intumescent pipe wrap used to maintain the fire rating of walls where they have been penetrated by plastic pipes and/or metallic pipes with combustible insulation. It can be cut to length on site.

This amazing product can be used in both masonry walls and plasterboard partitions

Roll size - 50mm wide x 2mm thick x 25m long


Features & Benefits

  • Up to 2 hour fire rating (EI120)
  • Supplied in a 25m coil and cut to length on site
  • No mechanical fixings required
  • Suitable for use in flexible walls and rigid walls
  • Suitable for PVC, HDPE and PP Pipes Suitable for plastic pipes up to 160mm diameter
  • Suitable for use around metal pipes with insulation
  • Suitable for use around pipe insulation up to 50mm thick
  • Suitable for use in Fire Batts
  • Performance unaffected by weathering (Type X Durability)

Regulations

  • Tested to BS EN 1366-3:2009
  • Classified According to EN 13501-2: 2007 + A1: 2009
  • Type X Durability Testing
Please note this product is not tested for use in floors/ceilings - horizontal applications.

Availability: In stock

Regular Price: £106.80

Special Price: Excl. VAT: £81.59 Incl. VAT: £97.91

OR

Details

Application

The product is intended to be wrapped around the outside diameter of the combustible pipework or the outside diameter of the insulation. The tape supplied can be used to secure and hold the QuelCoil in place. Depending on the penetrating service, multiple layers of QuelCoil may be required. The number or layers and the positioning of the QuelCoil is detailed below. Firstly, check that the pipe and the substrate are clean and clear of any debris. Install the correct number of layers of QuelCoil for the service type ensuring that it is flush to the wall face or flush to the face of the QuelStop Fire Batt. The QuelCoil Intuwrap should be installed to both sides of the wall or, for applications with double layer or pattress fitted QuelStop Fire Batt, the QuelCoil should be within the thickness of each QuelStop Fire Batt. Under fire conditions, the QuelCoil Intuwrap expands and fills the void left by the burnt plastic / insulation.

 

For all insulated non-combustible pipes 2 layers of QuelCoil should be installed around the insulation (maximum insulation thickness is 50mm).